Sunny Shutter / Fabric & Testing

Fabric selection.
Documented
performance.

Fire-retardant curtain fabric selection, NFPA 701 test reports and documentation support for commercial projects. Bring us your specification. We’ll help match the material, test requirements and project use.

01 / Independent laboratory records

NFPA 701 testing.
Traceable results.

Sunny Shutter holds independent reports from Applied Lab and CTT Group for the materials below. Each record identifies the submitted material and the conditions under which it was tested.

Submitted material

100% polyester
blanket material

Client identification: Item 1, fire-retardant polyester blanket material.

Method & conditionNFPA 701 (2023) · Test Method 1

Initial condition.
Single-layer configuration.

Result: Complies

Applied Lab · May 14, 2026

Report 26-001467 · Revision 1

Submitted material

Polyester after
five laundering cycles

The same client material identification, evaluated after the reported care procedure.

Method & conditionNFPA 701 (2023) · Test Method 1

After laundering: 5 cycles.
Single-layer configuration.

Result: Complies

Applied Lab · May 14, 2026

Report 26-001467 · Revision 1

Submitted material

550 denier
100% nylon fabric

Fire-retardant, heat-set nylon.
Laboratory sample identification: CTT #1.

Method & conditionNFPA 701 (2023) · Test Method 1

As received.
Lengthwise specimens.

Result: Pass

CTT Group · May 20, 2026

Report 7285-002T-1A-en

These are material test records held by Sunny Shutter. Results apply to the submitted samples and reported conditions. Relevance to a proposed curtain fabric, lining or finished assembly is reviewed before the report is included in a project submission.

Request Relevant Reports

02 / From specification to selection

The right fabric.
For the actual application.

Appearance, light control and documented performance belong in the same review. We help work through fabric options and the evidence needed for the intended commercial use.

Light & privacy

Define the room’s purpose.

Clarify whether the project needs blackout, filtered daylight, privacy or glare control. Include lining, overlap and edge conditions when reviewing the complete window treatment.

Construction & finish

Identify the material.

Match the proposed fabric reference, fibre composition, coating or treatment, colour and layer arrangement to the available documentation.

Use & maintenance

Plan for its working life.

Discuss daily handling, cleaning methods and any required durability testing. Confirm care instructions for the selected material and any flame-retardant treatment.

03 / Supporting material data

Beyond a single
test result.

The report set also includes care, abrasion, tear and apparel-flammability evaluations. These records answer different questions and are reviewed against the intended application.

Care procedure & post-laundering testing

The polyester NFPA 701 record identifies testing after five laundering cycles. A supporting worksheet records a 63°C water setting and normal tumble drying.

This documents the reported test sequence. Care instructions for a selected curtain fabric, and any further cleaning or retesting requirement, must be confirmed separately.

Applied Lab · 26-001467 · Revision 1 · May 14, 2026
Martindale abrasion · ASTM D4966-22

Three specimens of the submitted 550D nylon were evaluated at 20,000 cycles. The report records no breakage or appreciable wear at that point, using 12 kPa pressure and foam backing.

The report’s conclusion is Low Traffic / Private Spaces under the cited ACT upholstery guideline. It does not establish a High Traffic / Public Spaces rating or a service-life guarantee.

Applied Lab · 26-001468 · Revision 1 · May 14, 2026
Elmendorf tear resistance

CTT Group evaluated warp and weft tear resistance for the submitted white 550 denier nylon under CAN/CGSB-4.2 No. 12.3-2005 / ISO 13937-1:2000.

The report includes an instrument measuring-range qualification. Review the complete record and its remarks when comparing results with a project’s tear-strength requirement.

CTT Group · 7285-001T-1A-en · May 11, 2026
Apparel flammability · ASTM D1230-25

Separate reports for the submitted polyester and nylon materials record Class 1, Normal Flammability, under ASTM D1230-25 / 16 CFR 1610.

This classification relates to the reported apparel-textile test. It is separate from NFPA 701, CAN/ULC-S109 and building-material classifications.

Applied Lab · 26-001467 and 26-001468 · Revision 1 · May 14, 2026

04 / Contractor & designer support

A clearer path
to project documentation.

Send the relevant specification early. We can review existing records, coordinate suitable fabric options and discuss additional third-party testing where needed.

Review the requirement.

Identify the required standard and edition, material use, fabric schedule, cleaning requirements and document submission deadline.

Match the evidence.

Check the proposed material and construction against existing reports. Identify where a different sample, configuration or test is needed.

Prepare the package.

Coordinate available reports, fabric references, samples and care information for review by the project team before production.

Documents to coordinate

Fabric sample & reference · Composition & construction · Relevant laboratory report · Care information · Proposed use & configuration

Technical FAQ

Understand the record.
Specify with clarity.

The material, test method and intended use determine which documentation belongs in your project package.

Can you supply NFPA 701-tested curtain fabrics?

We can help select curtain fabrics with relevant NFPA 701 documentation and review whether an available report matches the proposed material and configuration. The records listed above are examples for specific submitted materials; they are not a blanket approval of every fabric in our collections.

What if the specification requires CAN/ULC-S109?

Send the required standard and edition with your specification. We will review the documentation needed for the proposed fabric and discuss testing where required. NFPA 701 and CAN/ULC-S109 are separate standards; an NFPA 701 report alone does not establish CAN/ULC-S109 compliance.

Can you help with a custom or specified fabric?

Yes. Share the fabric reference, supplier information, composition, colour, intended use and required test standard. We can review available evidence and discuss material alternatives or additional third-party testing. Suitability and acceptance depend on the selected material and test results.

Does a passing flame test mean the fabric is fireproof?

No. A passing result describes the submitted sample’s performance under the specified test conditions. It does not mean a fabric cannot burn or establish the fire performance of an entire room or installation.

Does the five-cycle result cover every cleaning method?

No. It applies to the submitted polyester material after the laundering sequence identified in that report. Follow the care instructions and maintenance requirements established for the selected fabric; a different cleaning method or material needs its own review.

How do I request the relevant test documentation?

Send the fabric reference, intended use and required test standard by email or WhatsApp. Our team will identify the applicable records and advise what further material information or testing may be needed.

Start with your specification

Let’s review
what your project needs.

Send your fabric schedule or the relevant tender pages. We’ll help identify suitable materials, available test documentation and the next steps for your commercial project.

Include: project location · intended use · fabric reference · required standard · submission deadline